TENNESSEE EQUIPMENT MODERATED NEWSGROUP AND LIST   >   East Cost   >   Maryland   >   Auctions   >   Fluke philips PM2811 power supply, 30V, 10A

Fluke philips PM2811 power supply, 30V, 10A


Fluke / Philips PM2811 Autoranging DC Power Supply, 30 V, 10 A
* Description: The Fluke Philips PM2811 is a Single Output DC Power Supply with the following specifications:
OUTPUT module 30 V - 10 A - 60 W
Output Voltage range 0 to 30 V
Output Current range 0 to 10 A
Overvoltage protection range 2 to 32 V
Accuracy (at calibration temperature)
Output Voltage ± (0.04 % of setting + 10 mV
Output Current ± (0.1 % of setting + 50 mA
Over Voltage Protection ± (0.5 % of setting + 150 mV
Output Voltage (0.016 % of setting + 2 mV)/K
Output Current (0.05 % of setting + 2 mA)/K
Long term drift (in an 8 hour period)
Output Voltage 0.04 % of setting + 5 mV
Output Current 0.05 % of setting + 10 mA
Programming Resolution (12bit)
Output Voltage 7.5 mV/LSB
Output Current 2.5 mA/LSB
Over Voltage Protection 7.5 mV/LSB
Source Effect (for any line voltage change within rating)
Voltage ± (0.01 % of setting + 2 mV)
Current ± (0.02 % of setting + 2 mA)
Load Effect (load change 10 % to 90 % or 90 % to 10 % full load)
Constant Voltage ± (0.01 % of setting + 5 mV)
Constant Current ± (0.02 % of setting + 5 mA)
Load cross regulation Negligible for both voltage and current
Constant Voltage pp/rms 15 mV/3 mV
Constant Current rms 10 mA
Switching Frequency approx. 20 kHz approx.
READBACK ACCURACY:(referred to the output terminals)
Accuracy (at calibration temperature)
Voltage ± (0.05 % + 25 mV)
Current ± (0.1 % + 30 mA)
Measuring Resolution (12 bit)
Voltage resolution to interface 7.5 mV
Current resolution to interface 2.5 mA
Voltage resolution to display 10 mV
Current resolution to display 10 mA
Max. Current at Reverse voltage 10 A
REMOTE SENSE > 0.25 Volt drop per lead (at open sense connections, the output voltage will not be more than 3 V above the programmed value)
DYNAMIC OPERATION ÆI=1 A between 1 and 10A between 0.5 and 5A between 1 and 10A
Programming response (measured with resistive load)
Up (0 V to max. output) 100 ms @ 2 A
Up (0 V to max. output) 50 ms @ (no load)
Down(max. output to 1 V) 100 ms @ 2 A
Down (max. output to 1 V) 50 ms @ (no load)
Step Interval time up to 60 s
* Working Condition: Presumed Good but Untested
* Other Comments / Notes: None