* Tested and Working within Manufacturors Specifications
The Model PM2002 is a dual channel high performance power meter that features high speed measurement capability and wide dynamic range.
Frequency Range ..........................................................10kHz-40GHz, power head dependent
Power Measurement Range ...........................................-70dBm to +44dBm, power head dependent
Number of Channels.....................................................Two
Measurement Speed......................................................1 channel : 200 readings/sec.
2 channels : 100 readings/sec.
Power Heads ................................................................Select from a large number of diode and thermocouple Power Heads. The
linearity and frequency calibration factors for the heads are provided in an
Dynamic Range ............................................................Up to 90dB with diode heads, 50dB with thermocouple heads. See Power Head
Inputs ...........................................................................Rear panel HEAD connectors and rear panel IEEE-488 connector standard.
Outputs ........................................................................Rear panel PWR/REF connector, 0dBm, 50MHz.
Rear panel RECORDER BNC connector, 0 to 10V into 1M
Output impedance is 9.09kΩ. May be operated into 1kΩ or 1V fs.
Emulation .....................................................................HP437, HP438 and Boonton 4220A
Displays........................................................................Menu-driven 20 character x 4 line LCD display. Simultaneous display of dual
channels with bar graph proportional to data display.
Display Units.................................................................Absolute, watts and dBm. Relative, dBr
Display Resolution.........................................................5 digits, nW, μW, mW and W; 4 digits dBm
Measurement Accuracy .................................................Total accuracy is the sum of the following uncertainties: (errors are ± worst case).
Instrumentation Accuracy...............................................0.23% of full scale. 0.46% of 1/10 full scale
Output Frequency: .................................................50MHz ± 1.5%.
Output Level: .........................................................0dBm (1mW) Level Accuracy: 0.03dB (±0.7%) (25°C) for 90 days.
0.051dB (±1.2%) worst case (0° to +55°C) for 1 year.
Source Impedance: ................................................50 ± 1 ohm. SWR: <1.05
Harmonic Output ...................................................<-50dBc.
Other Uncertainties .......................................................For Head, Noise, High Frequency Calibration Uncertainty See Power Head
Calibration Factors........................................................+3dB to -3dB in 0.01dB steps. These calibration factors are stored in nonvolatile
memory. When a frequency other than that stored is used, the meter
linearity interpolates between the calibration factor above and below the
frequency entered to obtain a calibration factor.
Sold with 7 day right of return if unsatisfied.